Bubble Size Distribution In Gas-Liquid Dispersion Column

Main Article Content

Thamer J. Mohammed
Fadi Z. Hanna
Ihsan B. Hamawand

Abstract

The present work investigates the effect of; superficial air velocities of: 1, 3, and 6 cm/s for two types of perforated distributor on hydrodynamic characteristic in a gas-liquid dispersion column of; air-water, and airaqueous-n-propanol solution. Bubble distribution, gas holdup, and power consumption are parameters take in consideration. Experimental work was carried out in perspex column of 8.5 cm inside diameter and 1.5 m height. Two types of bubble generator (perforated plate) were fixed at the bottom of the column; plate A (99 holes of 0.5 mm diameter and free area of 0.34%), plate B (20 holes of 1.5 mm diameter and free area of 0.62%). Photographic technique was used to measure the bubble parameters. The experimental results were represented by two empirical correlations. The gas holdup and the Sauter mean diameter of bubbles were correlated with both the power consumption and the hole diameter of the perforate plate.

Article Details

How to Cite
“Bubble Size Distribution In Gas-Liquid Dispersion Column” (2012) Journal of Engineering, 18(07), pp. 799–818. doi:10.31026/j.eng.2012.07.03.
Section
Articles

How to Cite

“Bubble Size Distribution In Gas-Liquid Dispersion Column” (2012) Journal of Engineering, 18(07), pp. 799–818. doi:10.31026/j.eng.2012.07.03.

Publication Dates

References

Akita, K., and Yoshida, F., (1974) ”Bubble Size. Interfacial Area, and Liquid Phase Mass Transfer Coefficients in Bubble Columns”,Ind. Eng. Chem. Proc. Des. Dev., 13, 84.

Bach, H.F., and Pilhofer, T., (1978) ”Variation of Gas Holdup in Bubble Columns with Physical properties of Liquids and Operating Parameters of Columns”, Germ. Chem. Eng., 1, 270. (Citied in Reference Shah et al. 1982).

Barnea, D., Shoham, O., Taitel, Y., (1980) ”Flow Pattern Characterization in Two Phase Flow by Electrical Conductance Probe”, Int. J. Multiphase Flow, 6, 387.

Bhavaraju, S.M., Russel, T.W.F., and Blanch, H.W., (1978), ”The Design of Gas Sparged Devices for Viscous Liquid System”, AIChE J., 24, 454-466.

Bouaifi, M., Hebrard, G., Bastoul, D., and Roustan, M., (2001), ”A comparative Study of Gas Holdup, Bubble Size, Interfacial Area and Mass Transfer Coefficients in Stirred Gas-Liquid Reactors and Bubble Columns”, Chem. Eng. and Proc., 40, 97-111.

Chaudhari, R.V., and Hofmann, H., (1994), ”Coalescence of Gas bubbles in Liquids”, Reviews in Chem. Eng., 10(2).

Colella, D., Vinci, D., Bagatin, R., Masi, M., and Baker, E.A., (1999),”A Study on Coalescence and Breakage Mechanisms in Three Different Bubble Columns”, Chem. Eng. Sci., 54, 4767-4777.

Dargar, P.,and Macchi, A., (2006), ”Effect of Surface-Active Agents on The Phase Holdups of Three-Phase Fluidized Beds”, Chemical Engineering and Processing, 45, 764-772.

Delhage, J.-M., and Melaughlin, J.B., (2003), Appendix 4: report of study group on microphysics, Inter. J. of Multiphase Flow 29, 1101-1116.

Hebrard, G., Bastoul, D., and Roustan, M., (1996), ”Influence of Gas Sparger on The Hydrodynamic Behaviour of bubble Columns”, Trans I Chem E., 74(A), 406-414.

Heijnen, J.J., and Riet, K.V., (1984), ”Mass Transfer, Mixing and Heat Transfer Phenomena in Low Viscosity Bubble Column Reactors”, Chem. Eng. J., 28, B21-B42.

Hikita, H., Asai, S., Tanigawa, K., Segawa, K., and Kitao, M., (1980) ”Gas Holdup in Bubble Column”, Chem. Eng. J., 20, 59.

Kantarci, N., Borak, F., and Ulgen, K.O., ( 2005), ”Bubble column reactors”, Process Biochemistry,40, 2263-2283.

Krishna, R., and Ellenberger, J., (1996), ” Gas Holdup in Bubble Column Reactors Operating in The Churn-Turbulent Flow Regime”, AIChE J., 42, 2627-2634.

Levan, M.D., and Newman, J., (1976), ”The Effect of Surfactant on The Terminal and Interfacial Velocities of a Bubble or Drop” , AIChE J., 22, 695-700.

Malysa, K., Krasowska, M., and Krzan, M., (2005), ” Influence of Surface Substances on Bubble Motion and Collision with Various Interfaces”, Advance in Colloids Interface Science 114-115, 205-225.

Mandal, A., Kundu, G., and Mukerjee, D., (2003), ”Gas Holdup and Entrainment Characteristics in a Modified Dawn Flow Bubble Column with Newtonian and Non-Newtonian Liquid”, Chem. Eng. and Processing, 42,777-787.

Mouza, A.A., Dalakoglou, G.K., and Paras, S.V., (2005),”Effect of Liquid Properties on The Performance of Bubble Column Reactors with Fine Pore Spargers”, Chem. Eng. Sci., 60, 1465-1475.

Polli, M., Di Stanislao, M., Bagatin, R., AbuBakr, E., and Masi, M., (2002), ”Bubble Size Distribution in The Sparger Region of Bubble Columns”, Chem. Eng. Sci., 57,197-205.

Rodionow, A.I., and Patzelt, H., (1969),Wiss. Z. Tech. Hochsch. Lewna-Merseburz, 11, 435.

Tse, K.L., Martin, T., McFarlane, C.M., and Nienow, A.W., (2003),”Small Bubble Formation Via a Coalescence Dependent Break-up Mechanism”, Chem. Eng. Sci., 58, 275-286.

Similar Articles