Experimental Study of Pre-Cast Reinforced Concrete Deep Beams (Hallow Core section) Retrofitting with Carbon Fiber Reinforced Polymer (CFRP)
Main Article Content
Abstract
Experimental programs based test results has been used as a means to find out the response of individual elements of structure. In the present study involves investigated behavior of five reinforced concrete deep beams of dimension (length 1200 x height 300 x width150mm) under two points concentrated load with shear span to depth ratio of (1.52), four of these beams with hallow core and
retrofit with carbon fiber reinforced polymer CFRP (with single or double or sides Strips). Two shapes of hallow are investigated (circle and square section) to evaluated the response of beams in case experimental behavior. Test on simply supported beam was performed in the laboratory & loaddeflection, strain of concrete data and crack pattern of those five reinforced concrete beams was recorded. Parametric studies are also conducted in this study includes the effect of hallow opening (shapes and materials), and CFRP ratio (single, double strips and side horizontal stirrups). Comparisons of test results from experimental data are based on load capacity, deflection, crack pattern and strain of concrete for all beams. From this comparison it was found that hallow effect on strength capacity i.e. decrease by about (13%) and increased in deflection and strain by about (18%, 24%) respectively compared with solid section. Also find that CFRP give more enhancements in loading capacity by about(33 to 66%) and decreased deflection for same applied load by about (26%). Test results that show when sides of beams retrofit with CFRP strip against horizontal shear increased strength by about by (20%). Finally the using double CFRP strips for hallow section gives equivalent or more than strength capacity of solid section.
Article Details
Section
How to Cite
References
Nilson, A. H. , Darwin, D. and Dolan, C. W., "Design of Concrete Structure" McGraw-Hill Book Company 2006.
British Standard Institution (BS 8110), (1997) "Code of Practice for Design and Construction" British Standard Institution Part 1, London.
ACI 318M – 11: "Building Code Requirements for Reinforced Concrete, "ACI Committee 318M, 2011.
ASTM 2006, " American Society for Testing and Materials ".
Nimnim, H. T., "Structural Behavior of Ferrocement Box-Beams," M. Sc., thesis, University of Technology, 1993.
AASHTO LRFD (2005): "Bridge Design Specifications and Commentary (3rd Ed.) ". Washington, DC: American Association of State and
Highway Transportation Officials. Ashour, A.F., (2000),"Shear Capacity of Reinforced Concrete Deep Beams", ASCE Structural Journal,
September 2000, Vol. 126, No. 9, pp. 1045-1052.
Darwish, M.N., (1998),"Reinforced High Strength Concrete Deep Beams: Effects of Web Reinforcement", Proceedings of the Eighth
International Colloquium on Structural and Geotechnical Engineering, Cairo, Egypt 1998, pp. 99-112.
Austin, S., Robins, P., Pan, Y. (1995). "Tensile Bond Testing of Concrete Repairs.” Materials and Structures, 28(179), 249-259.
Oehlers, D. J., & Bradford, M. A. (1995). "Composite Steel and Concrete Structural Members". Kidlington, Oxford, U.K.: Elsevier
Science, Ltd.
Arockiasamy, M., Amer, A. and Shahawy, M. (1996) "Concrete beams and slabs retrofitted with CFRP laminates", Proceedings of the Eleventh Conference on Engineering Mechanics, ASCE, New York, USA, pp776-779.
ACI committee 440.2R-02, "Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete
Structures" American Concrete Institute, Michigan, USA, 2002,p.45.