EFFECT OF EXISTING FLANGE OPENINGS AND COLD JOINTS ON STRENGTH OF RC T-BEAMS
Main Article Content
Abstract
In the construction of modern buildings, a network of pipes and ducts is necessary to accommodate essential services like water supply, sewage, air-conditioning, electricity, telephone, and computer network. Passing these services vertically required creating openings in slab (Flanges of T-Beams) after or before construction.
New researches show that the concrete flanges provide a certain level of shear resistance above a certain width. Therefore, due to existing of these openings or cold joints in slab (Flange) and abrupt changes in the sectional configuration, opening corners are subject to high stress concentration that may lead to reduction in stiffness of the T-Beam and produced cracking and excessive deflection.
In the present research, shear behavior of reinforced concrete T-Beams which contains vertical opening (Flange openings) or cold joints at the flanges are studied as well as the effect of openings or cold joints locations. Eight beams were tested, one of which were constructed without any openings or cold joints (reference beam), while, the others were constructed with openings or cold joints in different locations.
Experimental results show that the presence of flange openings reduce the shear capacity about (22% to 32%) for beams containing one opening and about (17%-39%) for beams containing two openings. For beams containing cold joints, the shear capacity decreased about (27%) in comparison with reference beam.
Article Details
How to Cite
Publication Dates
References
ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08)”, American Concrete Institute, Farmington Hills, MI, 2008, pp.465.
ASTM, "Test Method for Compressive Strength of Cylindrical Concrete Specimens", (ASTM C39-96), American Society for Testing and Materials, 1996.
ASTM, "Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens ", (ASTM C496-79), American Society for Testing and Materials, 1979.
ASTM, "Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading)", (ASTM C78-75), American Society for Testing and Materials, 1975.
Dainel H.R., and McMullen A.E., "Torsion in Concrete Beams Containing an Opening”, Journal of the Structural Division, ASCE, Vol.103, No.ST3, March 1977, PP. 607-617.
Giaccio, C., Al-Mahaidi, R. and Taplin, G., “Flange Effectiveness in Shear Strength of RC T-Beams”, Department of Civil Engineering, Monash University, Wellington Road Clayton, Vic. Australia, 2003,10 pp.
McCormac, J. C. and Nelson, J. K., “Design of Reinforced Concrete”, 7th Edition, John Wiley & Sons, Inc., USA, 2006, 721 pp.
Mansur, M.A., "Design of Reinforced Concrete Beams with Web Openings", Faculty of Civil Engineering, Universiti Teknologi, 81310 UTM Skudai, Malaysia, (Proceeding of the 6th Asia- Pacific Structural Engineering and Construction Conference, Kuala Lumpor, Malaysia ,5-6 September, 2006).
Nawy, E. G. , “Reinforced Concrete –A Fundamental Approach”, 6th Edition, Pearson Education International, New Jersey, USA, 2009, 933 pp.
Wang. C. K. and Salmon, C. G. , “Reinforced Concrete Design”, 4th Edition, Harper