Analysis of Shell and Double Concentric Tube Heat Exchanger Using CFD Application
Main Article Content
Abstract
This study focuses on CFD analysis in the field of the shell and double concentric tube heat exchanger. A commercial CFD package was used to resolve the flow and temperature fields inside the shell and tubes of the heat exchanger used. Simulations by CFD are performed for the single shell and double concentric tube.
This heat exchanger included 16 tubes and 20 baffles. The shell had a length of 1.18 m and its diameter was 220 mm. Solid Works 2014, ANSYS 15.0 software was used to analyze the fields of flow and temperature inside the shell and the tubes. The RNG k-ε model was used and it provided good results. Coarse and fine meshes were investigated, showing that aspect ratio has no significant effect. 14 million elements were used in the mesh. A comparison was made between the profiles of temperature and velocity for the experimental and results of the model and it had an acceptable adaptation.
Article received: 22/1/2018
Article accepted: 26/2/2018
Article published: 1/11/2019