Experimental and Theoretical Investigation of Noise Effect in Centrifugal Fan Impeller

Main Article Content

Manal Hadi Saleh
Muna Sabah Kassim
Amina Hmoud Hnaef

Abstract

In this work a study was made in centrifugal fan blower to investigate the effect of impeller blade design on sound pressure level (SPL). Shroud and unshroud impeller of nine blades are used. The sound generation from flow inside the test rig at different positions was displayed by using spectral analyzer. The experiments were carried out in anechoic chamber with small holes in its walls, under ambient condition about (25-27) C ° to avoid the effect of temperature on the sound pressure level. The results showed that (SPL) decreased with the increase of distance from the source about (3-4)dB when distance varied about (0.8-1.06)m, and the (SPL) decreased with the decrease of velocity about (8-12)dB when velocity varied between (13000-2600) r.p.m., and when the velocity remain constant (SPL) increased with the increased of pressure about (7-15)dB when the pressure varied between (36-8)mbar. For the purpose of comparison, two types of impellers were tested under same conditions, the results showed that (SPL) increased when shroud used on the impeller. The mathematical results show good agreement with the experimental results. The study also concluded a spectral analysis of the noise generated using 1/3 octave band filter. The analysis showed that (SPL) increased with frequency range of (0.8-400) Hz. The maximum sound pressure level was appeared clearly in the frequency range between 200 – 400 Hz .

Article Details

How to Cite
“Experimental and Theoretical Investigation of Noise Effect in Centrifugal Fan Impeller” (2014) Journal of Engineering, 20(02), pp. 87–105. doi:10.31026/j.eng.2014.02.07.
Section
Articles

How to Cite

“Experimental and Theoretical Investigation of Noise Effect in Centrifugal Fan Impeller” (2014) Journal of Engineering, 20(02), pp. 87–105. doi:10.31026/j.eng.2014.02.07.

Publication Dates

References

Barlow, J., Rae, W. and Pope, A. 1999, "Low Speed Wind Tunnel Testing", John Wiley& Sons.

Bartlett, F. "The Prpblem of Noise", 1934, Cambridg University Press.

Beranek, L., 1960,"Noise Reduction", Massachusetts Institute of Technology,.

Daniel Wolfram, Thomas Carolus, Michael Sturm, 2011, "Fan Tone Generation in an Isolated Rotor Due to Unstable Secondary Flow Structures", Pollrich Ventilatoren GmbH, 41065 Monchengladbach, University of Siegen, Departement of Fluid- and Thermodynamics, 57068 Siegen, Germany.

Faulkner, L.L., 1976,"Handbook Of Industrial Noise Control" industrial press. Inc,.

Holman, J.P., and Gajda, w.j., 1984, "Experimental Methods for Enginers", McGraw-Hill Book Company, Fourth Edition,.

Impeller Located Near A wedge, 2002, "DA Research Lab, LG Electronics Inc”, 327-23, Kasan- dong, Kumchon-gu, Seoul 153-802, South Korea.

J. A coust. Soc. Am., 1978, "Noise Generation in FC Centrifugal Fans", Volume 64, Issue S1, pp. S48-S48 America.

Jong- Soo Choi, 1993,"Aerodynamic Noise Generation in Centrifugal Turbo Machinery", The Pennsylvania State University, Korea.

Kuang-Hung Hsien, Shyh-Chour Huang, Sciences and Kaohsiung, Taiwan, 2011, "Taguchi Method to Robust Multi--Criteria Optimum Design for Ultra-Thin Centrifugal Fan", National Kaohsiung University of Applied.

Kunjur, A., Krishnamurty, S., 1997, "A Robust Multi-Criteria Optimization, Approach", vol.32, pp. 797-810, Mech. Mach. Theory.

Liu Xiaoliang, Qi Datong and Mao Yijun, 2008, "Noise Reduction for Centrifugal Fan with Non-Isometric Forward-Swept Blade Impeller" Higher Education Press and Springer-Verlag.

Soichi Sasaki, S., 2012, "An Experimental Study on Broadband Noise of a Propeller Fan ", pp.1-7, Nagasaki University's Academic.

Wan-Ho Jeona and Duck-Joo Leeb, "A numerical Study on the Flow and Sound Fields of Centrifugal impeller located near a wedge, DA research Lab., LG Electronics Inc., 32 7-23, Kasan-dong, Kumchon-gu, Seoul 153-802, South Korea.

Similar Articles