Mathematical Model for BOD in Waste Water Discharges from Al Dora Refinery in Baghdad

Main Article Content

Shatha Dh. AL Khazraji
Nawar O.A. Nasser

Abstract

This research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there
is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated that the best mathematical model is
BOD= 0.786 (ln(COD))^2 - 3.077E83/Exp(10T) + 1.76E+48/Exp(0.1TDS)- 5.6507/Exp(100Phe)
With correlation coefficient of 0.873. The presented research demonstrates many conclusions regarding the relation between BOD and other pollutions, it is clear that the relation between BOD and COD is a direct relation, while it’s a reverse relation with other pollutions and it’s also clear that a linear model can be used to represent the relation between BOD and COD for a value of COD approximately less than (50 mg/L).

Article Details

How to Cite
“Mathematical Model for BOD in Waste Water Discharges from Al Dora Refinery in Baghdad ” (2012) Journal of Engineering, 18(12), pp. 1297–1306. doi:10.31026/j.eng.2012.12.01.
Section
Articles

How to Cite

“Mathematical Model for BOD in Waste Water Discharges from Al Dora Refinery in Baghdad ” (2012) Journal of Engineering, 18(12), pp. 1297–1306. doi:10.31026/j.eng.2012.12.01.

Publication Dates

References

Abood, 2004, Waleed Mohammed, "Designing of Pilot Plant for Treatment of Waste Water Contaminated with Furfural by The Adsorption Method", a thesis submitted to the Environmental Engineering, College of Enginering ,University of Baghdad.

Al-Azzawi, 2007,Muwafaq Ahmed Abed, "Evaluation of The Performance of The Dora Refinery Waste Water Treatment Plant", a thesis submitted to the Environmental Engineering, College of Engineering, University of Baghdad.

Al Dora Refinery web site,2012, http://www.dauramrc.com

CINER ,F., SARIOGLU, M. ,2005,"DETERMINATION OF INERT CHEMICAL OXYGEN DEMAND (COD) FRACTIONS OF CUMHURIYET UNIVERSITY WASTEWATER", Cumhuriyet University, Department of Environ. Eng. 58140,Sivas, Turkey,Selected from papers presented in 9th, International Conference on Environmental, Science and Technology (9CEST2005), 1-3 September 2005, Rhodes island, reece

I. Pasztor;etal. 2010, I. Pasztor; P. Thury; J. Pulai, " Chemical oxygen demand fractions of municipal wastewater for modeling of wastewater treatment",Department of Environmental Engineering and Chemical Technology, University of Pannonia, Veszprem, Hungary.

Jenkins, S. H., 2001," Water quality management",Pergamon Press, NewYork. NGRDC,2000, Northeast Georgia Regional Development Center, Appendix B, Description Of Commonly Considered Water Quality Constituents, Watershed Protection Plan Development Guidebook

Pedro ,2004, Pedro Sérgio Fadini a, Wilson F. Jardimb and José Roberto Guimarães J. ," Evaluation of Organic Load Measurement Techniques in a Sewage and Waste Stabilisation Pond",Braz. Chem. Soc., Vol. 15, No. 1, 131-135, 2004. Printed in Brazil - ©2004 Sociedade Brasileira de Química, 0103 - 5053 $6.00+0.00

Rose, J., 1998, "Water and the environment". Gordn and Breach Science Publishers, Philadelphia, USA, 1-15

S. M. T. Sadatipour, L. Mirzaie and A. A.Rezaei,2009," An investigation on Kangan gas refinery wastewater", Department of Marine Science and Technology, Islamic Azad University, Tehran North Branch, Tehran, Iran National Iranian Gas Company, Research and Development Division, Tehran, Iran Int. J. Environ. Sci. Tech., 6 (1), 51-56.

Walters, M.,2009, Munde Walters, Ganesh Raj Osti, Nguyen Diem Hang," Determination of Chemical Oxygen Demand (COD) of Waste Wate

Similar Articles

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)