A GALVANOSTATIC POLARIZATION INVESTIGATION OF STEEL CORROSION IN ALKALINE SOLUTIONS

Main Article Content

Aprael S. Yaro

Abstract

The electrochemical behavior of iron and steel in alkaline media is complex,not well understood.It is
difficult to determine corrosion rates of steel in high pH solutions by extrapolation of Tafel curves.Polarization resistance (Rp) must be determined in some other way.In this study an attempt was made to find (Rp) values of steel corroding in saturated Ca(OH)2 by anodic currents impressed galvanostatically to the steel from a counter electrode placed together with a reference electrode(I.e. impressed anodic current densities were (10,20,40,and 100µA/Cm2 and duration time was about 25 minutes). It was found that this rapid and non destructive polarization technique yields accepted and reasonable information on corrosion behavior.

Article Details

Section

Articles

How to Cite

“A GALVANOSTATIC POLARIZATION INVESTIGATION OF STEEL CORROSION IN ALKALINE SOLUTIONS” (2008) Journal of Engineering, 14(03), pp. 2752–2762. doi:10.31026/j.eng.2008.03.16.

References

* Stern,M. and Geary,A.L.( 1957),J.electrochem.Soc.,Vol.104,56.

* Stern,M. (1958) , Corrosion Vol.14,329.

* Ibid(1958) Corrosion Vo;.14,440.

* Mansfeild,F.(1976) Advance in corrosion science & technology,Vol.6,p.163-262,plenum press,New York.

* Callow,L.M.,Richardson ,J.A. & Dawson,J.L.(1976) corrosion ,J.,11,132.

* Mansfeild,F. & Oldham , K.B.(1971),corros.sci.11,787.

* Gonzalez,J.A.,Molina,A.,Escudero,M.L. and Andrade,C.(1985),J.corros.sci.,Vol.25,No.10.

* Newton,C.J.& Sykes,J.M.(1988) j.corros.sci.Vol.28,No.11.

* Elesener,B.,Wojtas,H.,Bohni,H.(1994),galvanostatic pulse measurement rapid on site corrosion monitoring"proceeding of international conference held in the Univ. of Sheffield ,24-28 July .

* Gouda,V.K.,(1970) , Br.corros.J.,Vol.5,P.198.

* Abd-El-Haleem, S.M. and Abd-Aal,E.E.(2006) electrochemical behavior of copper in alkaline sulfide solutions,corrosion,Vol.62,NO.2,P.121-128.

* Andrade,C.,Castillo V.,Alonso C., and Gonzalez J.A(1984) The determination of corrosion rate of steel embedded in concrete by polarization resistance and AC impedence methods,American society for testing and materials Philadelphia,P.43-63.

* Moosavi A.N.,John G.,and Gedge J. (1994) assessment of corrosion of refrigerant tubes in reinforced concrete eyes ring using corrosion mapping,Sheffield academic press,Sheffield ,Vol.1,p.116-127

Similar Articles

You may also start an advanced similarity search for this article.