SOLAR WATER HEATER WITH SHELL AND HELICAL COILED TUBE HEAT EXCHANGER AS A STORAGE TANK

Main Article Content

Karima E. Amori
Faiz F. Mustafa
SAHAR MAJEED

Abstract

In this work an experimental study is performed to evaluate the thermal performance
of locally made closed loop solar hot water system using a shell and helical coiled tube
heat exchanger as a storage tank. Several measurements are taken include inlet and outlet
temperatures of both collectors and supply water and temperature distribution within the
storage tank. This is beside the water flow rate in both collectors and load cycle. The
main parameters of the system are obtained.

Article Details

Section

Articles

How to Cite

“SOLAR WATER HEATER WITH SHELL AND HELICAL COILED TUBE HEAT EXCHANGER AS A STORAGE TANK” (2011) Journal of Engineering, 17(05), pp. 1213–1222. doi:10.31026/j.eng.2011.05.13.

References

Duffi J. A.,and Beckman W. A. (1974)"Solar Energy Thermal Process ", John Wiley & sons Inc. New York.

Khalifa A. N.,(1999),"Thermal Performance Of Locally Made Flat Plate Solar Collectors Used As Part Of A

Domestic Hot Water System", Energy Conversion & Management 40, PP. 1825-1833

Klett D.E.,Goswami D.Y.,and Saad M.T. (1984),"Thermal Performance Of Submerged Coil Heat Exchangers Used

In Solar Energy Storage Tanks", Journal of Solar Energy Engineering, Aug., vol. 106, PP. 373-375

Lunde P. (1980) ,"Solar Thermal engineering, Space heating and hot Water Systems", John Wiley & sons Inc. New York.

Myrna Dayan, (1997),"High Performance In Low Flow Solar Domestic Hot Water Systems", MSc. Thesis Mechanical Engineering University of Wisconsin-Madison.

Shokouhmand H., Salimpour M.R. and Akhavan-Behabadi M.A.,(2008),"Experimental Investigation Of Shell And Coiled Tube Heat Exchangers Using Wilson Plots", International Communications In Heat And Mass Transfer, 35, PP. 84-92

Similar Articles

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

<< < 1 2