Discharge Coefficient of Contracted Rectangular Sharp-Crested Weirs, an Experimental Study
محتوى المقالة الرئيسي
الملخص
An experimental study is made here to investigate the discharge coefficient for contracted rectangular Sharp crested weirs. Three Models are used, each with different weir width to flume width ratios (0.333, 0.5, and 0.666). The experimental work is conducted in a standard flume with high-precision head and flow measuring devices. Results are used to find a dimensionless equation for the discharge coefficient variation with geometrical, flow, and fluid properties. These are the ratio of the total head to the weir height, the ratio of the contracted weir width to the flume width, the ratio of the total head to the contracted width, and Reynolds and Weber numbers. Results show that the relationship between the discharge coefficient and these variables is a non-linear power function with a determination coefficient of 0.97. The importance and normalized importance analysis show that 56.3 % of the discharge coefficient variation is explained by the head-to-contracted width of the weir ratio followed by lower effects of the other variables, namely 16.5, 13.7, 12.4, and 1.2 % for contracted width to flume width ratio, Reynolds number, the head to the contracted width ratio, and Weber, respectively. The effect of the Weber number on the discharge coefficient is much lower than that of the Reynolds number.
تفاصيل المقالة
كيفية الاقتباس
تواريخ المنشور
المراجع
Al-Hassani, N. Z., and Mohammad, T. A., 2021. Impact of the Weir Slit Location, the Flow Intensity and the Bed Sand on the Scouring Area and Depth at the Dam Upstream, Journal of Engineering, 27(5), pp. 49–62. doi:10.31026/j.eng.2021.05.04.
Alwan, H. H., and Al-Mohammed, F. M., 2018. Discharge coefficient of rectangular notch using a dimensional analysis technique, 2nd International Conference on Engineering Sciences, IOP Conference Series: Material Science and Engineering, IOP Publishing, 433(2018) 012015. doi:10.1088/1757-899X/433/1/012015
Altan-Sakarya A. B., Kokpinar M. A, and Duru A., 2020. Numerical modelling of contracted sharp-crested weirs and combined weir and gate systems, Irrigation and Drainage, 69(4), pp. 854-864. doi:10.1002/ird.2468
Al-Zubaidy, R. Z., Kheder, K. I., and Darweesh, N. A., 2016. Energy dissipation on the ogee spillway by using direction diverting blocks, Journal of Engineering, 22(3), pp. 77-88. doi:10.31026/j.eng.2016.03.06
Aydin, I., Altan-Sakarya, A. B., and Ger, A. M., 2006. Performance of silt weir, Journal of Hydraulic Engineering, 132(9), pp. 987-989. Doi:10.1061/(ASCE)0733-9429(2006)132:9(987)
Aydin, I., Altan-Sakarya, A. B., and Sisman, C. J., 2011. Discharge formula for rectangular sharp-crested weirs, Flow Measurement and Instrumentation, 22(2), pp. 144-151. doi:10.1016/j.flowmeasinst.2011.01.003
Aydin, I., Ger, A. M., and Hincal, O. J., 2002. Measurement of small discharges in open channels by silt weir, Journal of Hydraulic Engineering, 128(2), pp. 234-237. doi:10.1061/(ASCE)0733-9429(2002)128:2(234)
Bos, M. G., 1989. Discharge measurement structures, Third revised edition, International Institute for Land Reclamation and Improvement/ILRI Wageningen, The Netherlands.
http://resolver.tudelft.nl/uuid:bed11d85-f4af-46d1-ba58-7d71f8c8f9c2
El-Alfy, K. S., 2005. Effect of vertical curvature of flow at weir crest on discharge coefficient, Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt.
Gharahjeh, S., Aydin, I., and Altan-Sakarya, A. B., 2012. Discharge formula for sharp-crested rectangular weirs, 10th International Congress on Advances in Civil Engineering ACE, Middle East Technical University, Ankara, Turkey. doi:10.1016/j.flowmeasinst.2011.01.003
Jaafar, R., 2009. Investigation of Water Flow Over Contracted Rectangular Flat-crested Slit Weir in Open Channel, Master thesis, Universiti Sains Malaysia. http://eprints.usm.my/41347/
Karim, R. A., and Mohammed, J. R., 2020. A comparison study between CFD analysis and PIV technique for velocity distribution over the Standard Ogee crested spillways, Heliyon, 6(10), pp. 1-9. doi:10.1016/j.heliyon.2020.e05165
Li, S., Yang, J., and Ansell, A., 2021. Discharge prediction for rectangular sharp-crested weirs by machine learning techniques, Flow Measurement and Instrumentation, 79, p. 101931. doi:10.1016/j.flowmeasinst.2021.101931
Mahtabi, G., and Arvanaghi, H., 2018. Experimental and numerical analysis of flow over a rectangular full-width sharp crested weir, Water Science and Engineering, 11(1), pp. 75-80. doi:10.1016/j.wse.2018.03.004
Munson, B. R., Young, D. F., and Okiishi, T. H., 2002. Fundamentals of fluid mechanics, 4th Edition, John Wiley & Sons, Printed in the United States of America.
Ramamurthy, A. S., Tim, U. S., and Rao, M. V. J., 1987. Flow over Sharp-Crested Plate Weirs, Journal of Irrigation and Drainage Engineering, 113(2), pp. 163-172. doi:10.1061/(ASCE)0733-9437(1987)113:2(163)
Tekade, S. A., and Vasudeo, A. D., 2016. Head discharge relationship of thin plated rectangular lab fabricated sharp crested weirs. Journal of Applied Fluid Mechanics, 9(3), pp. 1231-1235. doi:10.18869/acadpub.jafm.68.228.23128
U. S. Department of the Interior, 2001. Water measurement manual, 3rd edition, A Water