EFFECT OF STEEL FIBERS ADDITION ON THE BEHAVIOR OF HIGH STRENGTH CONCRETE CIRCULAR SHORT COLUMNS
محتوى المقالة الرئيسي
الملخص
loaded reinforced concrete circular short columns. An experimental investigation into the behavior
of 24 short reinforced concrete columns with and without steel fibers was carried out. The columns
had a circular section (200 mm diameter and 900 mm long). Test variables include concrete
strength, spacing of spiral reinforcement, and inclusion of steel fibers. The axial stress and axial
strains were obtained and used to evaluate the effects of the presence of steel fibers. It was found
that the addition of steel fibers slightly improves the load carrying capacity of the tested columns
whereas it significantly enhances the ductility of these specimens. Test results also indicated that for
the same confinement parameter , specimens with steel fibers has higher strength enhancement compared to specimens without steel fibers. For confinement parameter of 0.1 the strength enhancement equal 1.7 for specimens with fibers while it is 1.4 for nonfibrous specimens. An empirical expression is proposed and used to predict the confined strength of columns. It was shown that the proposed formula predicts the load carrying capacity of the tested columns reasonably.
تفاصيل المقالة
كيفية الاقتباس
تواريخ المنشور
المراجع
Al-Shamma Y. M. W., "Strength and Ductility of Confined Concrete Short Columns," M.Sc. Thesis, Al-Mustansiriya
University, Baghdad, Iraq, 2011, (presented and will be evaluated by the examining committee).
ASTM C1018, "Standard Test for Flexural Toughness and First-Crack Strength of Fiber-Reinforced Concrete (Using Beam
with Third-Point Loading)," Annual book of ASTM standards, Vol. 04.02, pp. 8, 1997.
Campione G., Fossetti M., and Papia M., "Behavior of Fiber-Reinforced Concrete Columns under Axially and Eccentrically
Compressive Loads," ACI Structural Journal, Vol. 107, No. 3, pp. 272-281, May-June 2010.
Foster S. J. and Attard M. M., "Strength and Ductility of Fiber-Reinforced High-Strength Concrete Columns," Journal of Structural Engineering, ASCE, Vol. 127, No. 1, pp. 28- 34, January 2001.
Foster S. J., " On Behavior of High-Strength Concrete Columns: Cover Spalling, Steel Fibers, and Ductility," ACI Structural
Journal, Vol. 98, No. 4, pp. 583–589, 2001.
Ganesan N. and Murthy J. V. R., "Strength and Behavior of Confined Steel Fiber Reinforced Concrete Columns," ACI
Materials Journal, Vol. 87, No. 3, pp. 221- 227, May 1990.
Hsu C. T. T., Hsu L. S. M., and Tsao W. H., "Biaxially Loaded Slender High-Strength Reinforced Concrete Columns with and
without Steel Fibers," Magazine of Concrete Research, Vol. 47, No. 173, pp. 299–310, 1995.
Kim S., “Behavior of High-Strength Concrete Columns,” PhD thesis, North Carolina State University, Raleigh, North
Carolina, pp. 205, 2007.
Li B. "Strength and Ductility of Reinforced Concrete Members and Frames Constructed Using High Strength Concrete." Res. Rep. No. 94-5, University of Canterbury, Christchurch, New Zealand, pp. 389, 1994.
Lima Junior H.C., Giongo J.S., "Steel Fibre High Strength Concrete Prisms Confined by Rectangular Ties under Concentric
Compression," Materials and Structures, Vol. 37, No. 10, pp. 689–697, 2004.
Mander J. B., Priestley M. J. N., and Park R., “Theoretical Stress-Strain Model for Confined Concrete,” Journal of StructurEngineering, ASCE, Vol. 114, No. 8, pp. 1804-1826, August 1988.
Marti P., Pfyl T., Sigrist V. and Ulaga T., "Harmonized Test Procedure for Steel Fibre-Reinforced Concrete," ACI Materials
Journal, Vol. 96, No. 6, pp. 676-685, 1999.
Martinez S., Nilson A. H., and Slate F. O., “Spirally Reinforced High-Strength Concrete Columns,” ACI Journal, Vol. 81, No. 5, pp. 431-442, Sep. 1984.
Razvi S. R. and Saatcioglu M., “Strength and Deformability of Confined High-Strength Concrete Columns,” ACI Structural Journal, Vol. 91, No. 6, pp. 678-687, 1994.
Razvi S., “Confinement on Normal and High Strength-Concrete Columns,” PhD Thesis, University of Ottawa, Ottawa, Canada, pp. 416, 1995.
Saatcioglu M. and Razvi S. R., “High- Strength Concrete Columns with Square Sections under Concentric Compression,”
Journal of Structural Engineering, ASCE, Vol. 124, No. 12, pp. 1438-1447, Dec. 1998.
Sheikh S. A. and Uzumeri S. M., “Strength and Ductility of Tied Concrete Columns,” Journal of Structural Engineering, ASCE, Vol. 106, No. 5, pp. 1079-1102, May 1980.
Tokgoz S., “Effects of Steel Fiber Addition on the Behavior of Biaxially Loaded High Strength Concrete Columns,” Journal of Materials and Structures, Vol. 42, No. 8, pp. 1125-1138, 2009.