EXPERIMENTAL SYUDY OF MIXED CONVECTION HEAT TRANSFER FOR A THERMALLY DEVELOPING AIR FLOW

محتوى المقالة الرئيسي

Yasin K.Salman
Ahmed J.Shkarah

الملخص

The investigation-included experiments were conducted to investigate the local and average mixed


convection heat transfer coefficient for thermally developing and fully developed hydrodynamically laminar airflow in an inclined annulus. The experimental setup, using an aluminum annulus having a radius ratio of (0.41) and the inner tube with a heated length of (0.85m) with constant wall heat flux boundary conditions. The investigation covered Reynolds number range from (332 to 1128) and heat flux varied from (82w/m² to 545w/m2). The air is developed hydrodynamically by using the entrance section annulus (calming section) having the same inner and outer diameter as a test section but with variable lengths. The entrance sections included a long calming section with a length of 90 cm (L/D 20.93) and short calming section with lengths of 60 cm (L/D=13.95). The results obtained represent the temperature distribution along the inner tube surface, the local and average Nusselt number distributions with the dimensionless axial distance (Z). For all annulus orientations and all entrance sections, the results show an increase in the Nusselt number values as the heat flux increases and as the aagle of the inclination moves from the vertical to the horizontal position. A comparison was made between the experimental results and the available previous work of Mataira, D. and Subba Raju, K. (1975), for the local Nusselt number distribution with the dimensionless axial distance (Z). The results obtained showed a good agreement and has the same trend that obtained in the previous work.

تفاصيل المقالة

كيفية الاقتباس
"EXPERIMENTAL SYUDY OF MIXED CONVECTION HEAT TRANSFER FOR A THERMALLY DEVELOPING AIR FLOW" (2005) مجلة الهندسة, 11(04), ص 683–699. doi:10.31026/j.eng.2005.04.06.
القسم
Articles

كيفية الاقتباس

"EXPERIMENTAL SYUDY OF MIXED CONVECTION HEAT TRANSFER FOR A THERMALLY DEVELOPING AIR FLOW" (2005) مجلة الهندسة, 11(04), ص 683–699. doi:10.31026/j.eng.2005.04.06.

تواريخ المنشور

المراجع

Bohne, D. and Obermeier, E. (1986), Combined free and forced convection in a vertical and inclined eylinder annuius, Int. Heat transfer conference 8", Vol.3, PP.1401-1406

Chen, Y.C and Chung, J,N (Feb 1998), 'Stability of mixed convection in a differentially heated vertical heated vertical channel, J. of Heat Transfer, Trans. of ASME,Vol.120, pp. 127-132.

Ciampi, M.; Faggiani, S.; Grassi, W.; Incropera, F.P, and Touni, G. (1986), Experimental study of mixed convection in horizontal annuli for low Reynolds numbers, Int. Heat Transfer Conference 8 Vol. 3, pp 1413-1418.

Cony J.E.R. and El-Shaarawi, M.A.I..(1975), Finite different analysis for kaminar flow heat transfer in concentrie annuli with simultaneously developing hydrodynamic and thermal boundary layers Int.J. For numerical methods in engineering, Vol. 9, pp.17-38.

Hashimoto, K. Akino, N. and Kawanrura, H. (1986), Combined forced -free convection heat transfer to a highly heated gas in a vertical annulus, Int.J.Ieat Mass Transfer. Vol.29, No.1, pp.145 151.

Hanzawa, T.; Sako, A.; Endo, H; Kagwa, M. and Koto,; K. (1986), combined free and forced laminar convective heat flux from isothermally hented inner tube in vertical concentric annulus. J.Chem. Eng. Japan, Vol.97, pp.78-81.

Holman, J.P. (1992), Heat Trunsfer. MeGraw- Hill Comp NewYork Huetz, J and petit, J.P. (1974), Natural and mixed convection in concentric annulus space Experimental and theoretiçal results for liquid metals, Int. Hent Transfer conference 5 Tokyo, Vol. 3, PP.169-172.

Kaviany, M. (1986), Laminar combined corvection in a horizontal annulus subject to constant heat flux inner wall and ndiabatic outer wall. J. of Heat Transfer, ASME Trans.. Vol. 108, pp. 392

Lundberg.RE; Reynoids. W.C and Mc Cuen, PA (1962), Heat transfer in annular passages. General formulation of the problem for arbitrarily wull temperature or heat fluxes, J. Heat Mass Transfer, Vol. 6, pp. 438-439

Maitra, D and Subba, K. Raju, (Feb 19751 combined free and forced convection Taminar heat transfer in vertical annulus, J. of Heat Transfer, Vol.97, No.1, PP.135-137

Ogupbe. V. and Baccow, H. (1979). A visual fow study of mixed convection in the entry region of avernical internally heated ansulus, IntJ. Heat & Fluid flow, Vol.1, No. 3. pp.115-120

Remash Krishnamurthy and Benjamin Gebhart. (1986), Heat transfer by mixed convection in vertical low undergoing tronsition. Int J Hea Mass Transfer, Vol 29. No. 8. pp 1211-1218

Roshenow W.M Hartnott and Ganie, (1985), Hand Book of Heat Transter Fundamentals McGiraw-Hill Comp., 2edition

Shai, Isaac and Barnca, Yacov (1986), Simple analysis of mixed convection with uniform heat flux Int.J. Heat Mass Transfer, Vol. 29, No.8, pp. 1139-1147.

Shah, R.K and London. A.L. (1978), Laminar Flow Forced Convection in Ducts, Advances in Heat Transfer, supplement 1.Academic press

Sherwin, K. and Wallis, J.D. (1972), combined natural and forced laminar convection for upflow through heated vertical concentric annuli, Thermodynamics and Fluid Mechanics Conference, Inst. Mechanical Engineers, pp.1-5.

Worsoe-Schmidt, P.M. (1967), Heat transfer in the thermal entrance region of circular tubes and annular passages with fully developed larminar flow.. Int.J.Heat Mass Transfer, Vol. 0, pp. 541 551

Zysina-Molozhen.L.M ; Psafonov, L.; Zebezhinskiy, L.D. and Fel'dberg, L.A. (1973), Heat transfer by combined forced and nataral convection in an annulus formed by tow coaxial cylinders. Heat transfer-Soviet Research, Vol.5, No 4