Field Study of Novel Storage Tank of Solar Water Heating System

Main Article Content

Karima Esmail. Amori
Jinan Shaker Sherza

Abstract

In this paper thermo-hydrodynamic characteristics were investigated experimentally for a new type shell-helical coiled tube heat exchanger used as a storage tank of closed loop solar water heater system. Triple concentric helical coils were made of copper tubes of (12.5mm OD and 10mm ID) with coils diameter of (207, 152.2, 97mm) for outer, middle and inner coils respectively. The experiments were carried out during a clear sky days of (March and April 2012). The parameters studied in this work are: history of average temperature of shell side of the storage tank, collector heat gain, heat rejected from coils to shell side of the storage tank, collector efficiency, thermal effectiveness of the heat exchanger (storage tank), and pressure drop. These parameters were studied at four different circulating mass flow rates of (1.8, 3, 6, 9 l/min) and for two consuming modes of supply water namely no withdrawal, and continuous withdrawal of (1 l/min). The results show that stratification temperature in the storage tank is increased for no withdrawal compared with water withdrawal, also the shell side average temperature increases with increased solar time. Collector efficiency is increased with increasing circulation flow rates, also increases with water withdrawn from storage tank. The pressure drop decreases with the increase of solar radiation .

Article Details

How to Cite
“Field Study of Novel Storage Tank of Solar Water Heating System” (2013) Journal of Engineering, 19(05), pp. 597–612. doi:10.31026/j.eng.2013.05.07.
Section
Articles

How to Cite

“Field Study of Novel Storage Tank of Solar Water Heating System” (2013) Journal of Engineering, 19(05), pp. 597–612. doi:10.31026/j.eng.2013.05.07.

Publication Dates

References

Agbo S.N., “Effect of Hot Water Withdrawal Rate on the Mean Temperature of a Themosyphon Solar Water Heater”, The Pacific J. of Sci. and Techn., V.7, No.2, pp.199-203,2006

ALI M.E., "Experimental investigation of natural convection from vertical helical coiled tubes" ,Int. J. Heat Mass Transfer. V.37,No.4,pp.665 - 671, 1994.

Jayakumar J.S., Mahajani S.M., Mandal J.C., Iyer K.N. , VijayanP.K.," CFD analysis of single-phase flows inside helically coiled tubes" , Computers and Chemical Engineering V.34, pp.430–446 , 2010.

Ghorbani N., Taherian H., MofidGorji , HessamMirgolbabaei, "An experimental study of thermal performance of shell-andcoil heat exchangers" , International Communications in Heat and Mass Transfer, V.37 pp.775–781 , 2010.

Kharat R., Bhardwaj N., Jha R.S. , "Development of heat transfer coefficient correlation for concentric helical coil heat exchanger" , International Journal of Thermal Sciences, V.48, pp. 2300–2308, 2009.

Mondol JD, Smyth M, Zacharopoulos A., “Experimental characterization of a novel heat exchanger for a solar hot water application under indoor and outdoor conditions”, Renewable Energy V.36, pp.1766-1779, 2011.

Rogers G.F.C., Mayhew Y.R., "Heat transfer and pressure loss in helically coiled tubes with turbulent flow", Int. J. Heat Muss Transfer V. 7, pp. 1207-1216.v 1964.

SalimpourM.R., "Heat transfer coefficients of shell and coiled tube heat exchangers", Experimental Thermal and Fluid Science, V.33 pp.203–207, 2009.

Seban R.A., Mclauchlin E.F., "Heat transfer in tube coils with laminar and turbulent flow", Heat mass transfer, V.6, pp.387-395, 1962.

Similar Articles

You may also start an advanced similarity search for this article.