Retrofitting Reinforced Concrete One–Way Damaged Slabs Exposed to High Temperature

Main Article Content

Shireen Awad Abbas
Amer Farouk Izzat
Jamal Abdulwahid Farhan

Abstract

Exposure of reinforced concrete buildings to an accidental fire may result in cracking and loss in the bearing capacity of their major components, columns, beams, and slabs. It is a challenge for structural engineers to develop efficient retrofitting techniques that enable RC slabs to restore their structural integrity, after being exposed to intense fires for a long period of time. Experimental
investigation was carried out on twenty one slab specimens made of self compacting concrete, eighteen of them are retrofitted with CFRP sheets after burning and loading till failure while three of them (which represent control specimens) are retrofitted with CFRP sheet after loading till failure without burning. All slabs had been tested in a simply supported span and subjected to two-point loading. The main variables were the effect of different temperature levels (300ºC, 500ºC and 700ºC),different concrete compressive strength (20MPa, 30MPa and 40MPa) and cooling rate (gradually and sudden cooling conditions) on the behavior of retrofitted one way slabs .The structural response of each slab specimen was investigated in terms of load-deflection behavior, ultimate load carrying
capacity and mode of failure. The experimental results, generally, indicate that slabs retrofitted using CFRP sheets restored flexural strength values nearly equal to or lower than those of the reference slabs, the retrofitted slabs exhibited larger deflection than the control slabs at ultimate loads. Retrofitted control slabs after loading regained about 93.95% to 97.92% of their original load capacity
(before retrofitting) while the other slabs regained from 42.% to 84% of the load capacity of the original control specimens. Most of the tested slabs failed by concrete crushing at mid span and partial debonding of certain retrofitting systems was also observed for a few cases

Article Details

How to Cite
“Retrofitting Reinforced Concrete One–Way Damaged Slabs Exposed to High Temperature” (2013) Journal of Engineering, 19(07), pp. 845–862. doi:10.31026/j.eng.2013.07.06.
Section
Articles

How to Cite

“Retrofitting Reinforced Concrete One–Way Damaged Slabs Exposed to High Temperature” (2013) Journal of Engineering, 19(07), pp. 845–862. doi:10.31026/j.eng.2013.07.06.

Publication Dates

References

• AN, W., Saadatmanesh, H. and Ehsani,M.R.(1991),” RC Beams Strengthened with FRP plates II: Analysis and Parametric Study”, Journal of Structural Engineering, ASCE, Vol.117, No. 11, 3434-3455.

• Arduini, M. & Nanni, A.( 1997),”Behaviour of precracked RC beams strengthened with carbon FRP sheets”,Journal of Composites for Construction,Vol.1,No.2, pp.63-70.

•Chan ,T. K. and Niall ,M.(2001),”Strengthening of One-way Slabs Using Carbon Fibre Plates: The Effect of Preload “,CSE Research Bulletin No. 14.

•Haddad, R.H., Mekhlafy, N. and AlAshteyat, A.M.(2011),” Repair of heat-damaged reinforced concrete slabs using fibrous composite materials” ,Construction and Building Materials, Vol. 25, Issue 3, pp 1213–1221.

•Hammadi, A. H., Izzet, A.F. and Farhan, J.A., (2012) ”Effect of Fire Flame (High Temperature) on the Self Compacted Concrete (SCC) One way Slab”, Journal of Engineering,Vol.18, No. 10 ,October 2012, ,pp 1083-1099.

•Kaur,S., Singh,B. Singh,S.P and Lal.R, (2007), “Analytical investigation on the strength and deformation characteristics of reinforced concrete beams”, IE(I) Journal – Civil Engineering, 87, pp 7 –12

•Karbhari, V.M., Seible, F., Seim, W.and Vasquez, A.(1999), “PostStrengthening of concrete slabs”,Proceedings of the Fourth International Symposium on Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures, Baltimore, Maryland, USA, pp1163-1173.

•Khomwan.N, Foster.S.J and Smith.S.T. ( 2005),” Debonding Failure in CFRP Flexurally Strengthened Reinforced concrete Beams”, Uniciv Report No. R-440 TheUniversity of New South Wales ,Australia,web(http://www.civeng.unsw.edu.au)

•Kim ,Y.J., Longworth, J.M., Wight R.G., Green M.F.(2010),” Punching Shear of Two-Way Slabs Retrofitted with Prestressed or Non-Prestressed

CFRP Sheets”. J. of Reinf.Plast. a.Compos., 29, 8, 1206-1223 .

•Klaiber, F.W., Wipf, J.J. and Kempers,B.J.(2003), "Repair of Damaged Prestressed Concrete Bridges using CFRP", Proceedings of the 2003 Mid Transportation Research Symposium,Ames, Iowa, Iowa State University,www.ctre.iastate.edu.

• McKenna, J.K.(1993), “Post strengthening of reinforced concrete members using fibre composite materials”, Msc Thesis, Department of Civil Engineering, Royal Military College of Canada, Kingston, Ontario, Canada.

•Meier, U.(1987), "Bridge Repair with High-Peformance Composite Materials",Material und Technik, Vol. 4, pp. 125-128 (in German).

• Mohammad, Reza. A, Christoph, C. and Masoud, M. (2007), “Debonding Failure Modes of Flexure FRP-Strengthened RC Beams”, Journals of composites: Part B Engineering, 39, pp 826-841.

• Mosallam ,S.A., Mosalam ,K.M.(2003),”Strengthening of Two-Way Concrete Slabs with FRP Composite Laminates”,Constr. a. Build. Mater., Vol. 17, pp.43-54

• Obaidat, Y.T., Heyden, S., Dahlblom.O., Abu-Farsakh, G., and AbdelJawad,Y.(2012),” Retrofitting of reinforced concrete beams using composite laminates”,Submitted to Construction & Building Materials.

• Rahimi, H. and Hutchinson,A.(2001),”Concrete beams strengthened with externally bonded FRP plates”,Journal of Composites for Construction,ASCE, 5(1): p 44-56.

• Ramanathan,K.N(2008),” Influence of FRP width-to-FRP spacingratio on bond performance of externally bounded FRP systems on one-way concrete slabs ” ,M.Sc. thesis submitted to Swanson School of Civil Engineering, University of Pittsburgh

• Saadatmanesh, H. and Ehsani, M.(1991), "RC Beams Strengthened with GFRP Plates. ZI: Analysis and Paramerric Study", Journal of Structural Engineering, ASCE, Vol.117 No. 11, pp. 3434-3455

• Sergio, F. B. and Beth ,M. M.(2004), “Effect of Carbon Fiber Reinforced Polymer Laminate Configuration on the Behavior of Strengthened Reinforced Concrete Beams”, Journal of Composites for Construction, Vol.8,No.3, pp 229-240.

• Shadhan,K.K., Abbas S. A. and Nabeel H.A.(2009),” Improving the Flexural Performance of Reinforced Concrete One-Way Slabs”, Journal of Babylon University, Pure and Applied Sciences, Vol.19 ,No.1,pp243-255.

• Shbeeba, Nadim I., Al-Akhrasb,Nabil M. Shannagc, Jamal.M &Alfendia ,Hatem R.(2012),”Strengthening of lightweight reinforced concrete slabs using different techniques”, The IES Journal Part A: Civil & Structural Engineering, Volume 5, pp 16-27.

* Smith, S.T and Kim S.J, (2009),“Strengthening of one way spanning RC slabs with cutouts using FRP composites ”,Journal of Construction and Building Materials,Vol.23, pp 1578-1590.

• Tan, K.H. & Mathivoli, M.,(1997),“Behaviour of precracked RC beams externally bonded with carbon fibre sheets”,Proceedings of the Third International Symposium on Nonmetallic (FRP)reinforcement for concrete structures”,Vol.1, Sapporo,Japan.

• Tann, D.B. (2003) ,“A semiempirical approach for the prediction of deflections of FRP strengthened RC slabs”, Proceedings of the Sixth International Symposium on FRP Reinforcement for Concrete Structures (FRPRCS-6), Singapore,pp357-366.

• Teng, J. G., chen, J. F.,Smith, s. t.and lam, l. (2002),”FRP Strengthened RC Structures” ,John Wiley and Sons Ltd, England.

• Zhang ,A., Jin ,W. and Li ,G.(2006),“Behavior of Preloaded RC Beams Strengthened with CFRP laminates”, Journal of Zhejiang University Science - A, Vol.7,No.3, pp 436-444.

Similar Articles

You may also start an advanced similarity search for this article.