Impact of Anchored CFRP Composites on the Strengthening of Partially Damaged PC Girders

محتوى المقالة الرئيسي

Hayder Qays Abbas
Alaa Hussein Al‐Zuhairi

الملخص

This manuscript investigated the effect of anchorage CFRP wrapping sheets, bolts, and laminate interlock on increasing the efficiency of flexural strengthening for the post-tension girder using CFRP composites techniques longitudinal laminates at the soffit for partially damaged loss of about 14.3% from its area of prestressed concrete beams, and the impact on restoring the original flexural capacity of PC girder. Mitigating delamination of the soffit of horizontal laminates (CFRP). The texture of the laminate and anchorages influenced the stress of the laminate carbon fiber, the mode of crack propagation and failure, and consequently, the beam's attitude has been investigated in this manuscript. The experimental findings demonstrated that using CFRP laminates significantly affects strand strain, especially when anchorage wrapping is applied. The laminates CFRP-EB enhanced the flexural capacity by around 13% of the original strength, which equates to a 13% increase in strand damage. Despite an increase in flexural capacity of 20%, 22%, and 29% when using anchorage wrapping, mechanical bolts, and laminate interlock, respectively. It has been proposed to use quasi-experimental equations to predicate the actual stress of un-grouted strands, considering the influence of CFRP laminate and wrapping anchorage sheets techniques only. The experiment outcomes demonstrated that using Anchored CFRP significantly affects load-carrying capacity and cracking load by up to 29% and delays the bonding failure.

تفاصيل المقالة

القسم

Articles

كيفية الاقتباس

"Impact of Anchored CFRP Composites on the Strengthening of Partially Damaged PC Girders" (2023) مجلة الهندسة, 29(08), ص 106–120. doi:10.31026/j.eng.2023.08.08.

المراجع

Abbas, H.Q., and Al‐Zuhairi, A.H., 2022. Usage of EB-CFRP for improved flexural capacity of unbonded post-tensioned concrete members exposed to partially damaged strands. Civil Engineering Journal, 8(6), pp. 1288-1303. Doi:10.28991/CEJ-2022-08-06-014.

Abbas, H.Q., and Al‐Zuhairi, A.H., 2022. Flexural strengthening of prestressed girders with partially damaged strands using enhancement of carbon fiber laminates by end sheet anchorages. Engineering, Technology & Applied Science Research, 12(4), pp. 8884-8890. Doi:10.48084/etasr.5007.

Abdulkareem, B.F., and Izzat, A.F., 2022. Serviceability of post-fire RC rafters with openings of different sizes and shapes. Journal of Engineering, 28(1), pp. 19-32. Doi:10.31026/j.eng.2022.01.02.

Abdulkareem, B.F., Izzet, A.F., and Oukaili, N., 2021. Post-fire behavior of non-prismatic beams with multiple rectangular openings monotonically loaded. Engineering, Technology & Applied Science Research, 11, pp. 7763-69. Doi:10.48084/etasr.4488.

ACI Committee 318-19. 2019. Building Code Requirement for Reinforced Concrete. American Concrete Institute.

ACI Committee 440-2R. 2017. Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures. American Concrete Institute.

Al-Hilali, A.M., Izzet, A.M., and Oukaili, N., 2022. Static Shear Strength of a Non-Prismatic Beam with Transverse Openings. Engineering, Technology & Applied Science Research, 12, pp. 8349-8353 Doi:.10.48084/etasr.4789.

Al-Zuhairi, A.H., Sahi, W.D., 2013. Numerical Prediction of Bond-Slip Behavior in Simple Pull-Out Concrete Specimens. Journal of Engineering, 19(1), pp. 1-12. Doi:10.31026/j.eng.2013.01.01

Daraj, A.J., and Al-Zuhairi, A.H., 2022. The Combined Strengthening Effect of CFRP Wrapping and NSM CFRP Laminates on the Flexural Behavior of Post-Tensioning Concrete Girders Subjected to Partially Strand Damage. Engineering, Technology & Applied Science Research, 12, pp. 8856-63. Doi:10.48084/etasr.5008.

El Meski, F.M., and Harajli, M.H., 2013. Flexural Capacity of FRP Strengthened Unbonded Prestressed Concrete Members: Proposed Design Guidelines. 11th International Symposium On Fiber Reinforced Polymers For Reinforced Concrete Structures (FRPRCS-11), 26-28 June 2013, hosted by University of Minho and ISISE, Guimarães, Portugal.

Hekmet, HM, and AF Izzet. 2019. Performance of segmental post-τensioned concrete beams exposed to high fire temperature. Engineering, Technology & Applied Science Research, 9( 4), pp. 4440-4447. Doi:10.48084/etasr.2864.

Jalil, A., and Al‐Zuhairi A.H., 2022. Behavior of Post-Tensioned Concrete Girders Subject to Partially Strand Damage and Strengthened by NSM-CFRP Composites. Civil Engineering Journal, 8(7), pp. 1507-21. Doi:10.28991/CEJ-2022-08-07-013.

Naqi, A.W., and Al-zuhairi, AH.. 2020. Nonlinear finite element analysis of RCMD beams with large circular opening strengthened with CFRP material. Journal of Engineering, 26(11), pp. 170-183. Doi:10.31026/j.eng.2020.11.11.

Nguyen-Minh, L., Phan-Vu, P., Tran-Thanh, D., Thi Truong, Q.P., Pham T.M.,, Ngo-Huu, C., and Rovňák. M., 2018. Flexural-strengthening efficiency of cfrp sheets for unbonded post-tensioned concrete T-beams. Engineering Structures, 166(1), pp. 1-15. Doi:10.1016/j.engstruct.2018.03.065.

Oukaili, N., and Buniya, M.K., 2013. Serviceability performance of externally prestressed steel-concrete composite girders. Journal of Engineering, 19(6), pp. 734-751. Doi:10.31026/j.eng.2013.06.06.

Razaqpur, G., and Mostafa, A.B., 2015. C-Anchor for strengthening the connection between adhesively bonded laminates and concrete substrates. Technologies, 3(4), pp. 238-258. Doi:10.3390/technologies3040238

Tam, A., Pannell, F.N., 1976. The ultimate moment of resistance of unbonded partially prestressed reinforced concrete beams. Magazine of Concrete Research, 28(97), pp. 203-08 Doi:10.1680/macr.1976.28.97.203.

المؤلفات المشابهة

يمكنك أيضاً إبدأ بحثاً متقدماً عن المشابهات لهذا المؤلَّف.