Numerical and experimental investigation on the performance of the capillary tube using R-134a and R-600a

محتوى المقالة الرئيسي

Qasim Saleh Mehdi
Baydaa Jaber Nabhan

الملخص

In this paper, isobutane (R-600a) is used as a suitable substitute for (R-134a) when changing the length of capillary tube. And the experimental data on capillary tube are obtained under different conditions such as (subcooling and ambient temperatures) on domestic refrigerator (9ft3 size), this data shows that (R-600a) a suitable substitute for (R134a) .The test presented a model for a steady state, two-phase flow in capillary tube for vapour compression system .The numerical model depends on conservation equations (mass, energy and momentum) as wall as the equation of state for refrigerant. The solution methodology was implemented by using finite difference techniques. The system results indicate that it is possible to change the refrigeration system using (R-134a) by shorter capillary tube length about (28.6%) when using (R-600a) .The theoretical results for different variables such as(subcooling and ambient
temperatures) showed a good agreement with the "ASHRAE" tables and experimental results.

تفاصيل المقالة

كيفية الاقتباس
"Numerical and experimental investigation on the performance of the capillary tube using R-134a and R-600a" (2012) مجلة الهندسة, 18(12), ص 1403–1420. doi:10.31026/j.eng.2012.12.08.
القسم
Articles

كيفية الاقتباس

"Numerical and experimental investigation on the performance of the capillary tube using R-134a and R-600a" (2012) مجلة الهندسة, 18(12), ص 1403–1420. doi:10.31026/j.eng.2012.12.08.

تواريخ المنشور

المراجع

• Ahmed Abdul-Nabi Omran, 2001, "Comparative Performance of Refrigerants R-22 & R-290 in Vapour Compression System and Steady the effects on the Capillary tube". M.Sc. Thesis, University of Technology.

• Bansal, P.K., Rupasinghi, A.S., 1998, "A homogeneous model for adiabatic capillary tubes". Applied thermal engineering, vol. 18, pp. (207-219).

• Bansal, P.K., Wang, G., 2004, "Numerical analysis of choked refrigerant flow in adiabatic capillary tubes". Applied thermal engineering, vol. 24, pp. (851-863).

• Beattie,D.R.H. and Whalley,P.B.,1981,"A simple two phase Frictional Pressure Drop Calculation Method". International Journal of Multiphase Flow, vol.8, pp.83-87.

• Chen, Z.H., Li, R.Y., Chen, Z.Y., 1990, "A correlation for metastable flow of refrigerant R-12 through capillary tubes". ASHRAE Trans., vol. 96, pp. (550-554).

• Churchill, S.W., 1977, "Frictional equation spans all fluid flow regions". Chemical Engineering, vol. 84, pp. (91-92).

• Fatouh, M., 2007, "Theoretical investigation of adiabatic capillary tubes working with propane/ n-butane/ isobutene blends". Energy Conversion and Management, vol. 48, pp. (1338-1348).

• Koizumi, H., Yokoyama, K., 1980, "Characteristics of refrigerant flow in a capillary tube". ASHRAE Trans., vol. 86, pt. 2, pp. (19-27).

• Li, R.Y., Chen,Z.H.,Lin,S.,Chen,Z,Y., 1990, "Metastable flow of R-12 through capillary tubes". International Journal of Refrigeration, vol. 13, pt. 3, pp. (181-186).

• Li Yang and Wen Wang, 2007, "A generalized correlation for the characteristics of adiabatic capillary tubes". International Journal of Refrigeration, pp. (1-7).

• Lin, S., Li,R.Y.andChen,Z.H., 1990, "Nnmerical modelling of thermodynamic non-equilibrium flow of refrigerant through capillary tubes". ASHRAE Transaction, vol.96, pt. 1, pp. (542-549).

• Mikol, E.P., 1963, "Adiabatic Single and Two-Phase Flow in Small Bore Tubes". ASHRAE Trans., vol. 5, pp. (75-86).

• Mohanraj, M.,Jayaraj,S.and Muraleedharan,C., 2002, "Improved Energy Efficiency for HFC-134a Domestic Refrigerator Retrofitted with

Hydrocarbon Mixture HC-290/HC-600a) as Drop in Substitute". National Institute of Technology, Calicut.

• Stoecker, W.F., and Jones, J.W., 1982, "Refrigeration and Air Conditioning". Mc Graw Hill, New York.

• Valladares, O.G., Segarra,C.D.and OlivaA., 2002, "Numerical simulation of capillary tube expansion devices behavior with pure and mixed refrigerants considering metastable region". Applied Thermal Engineering, vol. 22, pp. (379-391).

• Wongwises, S., and Pirompak, W., 2001, "Flow Characteristics of pure Refrigerants and Refrigerant Mixtures in Adiabatic Capillary Tubes". Applied Thermal Engineering, vol. 21, pp. (845-861).

المؤلفات المشابهة

يمكنك أيضاً إبدأ بحثاً متقدماً عن المشابهات لهذا المؤلَّف.