ESTIMATION OF EFFICIENCY OF REGENERATED GRANULAR ACTIVATED CARBON BY DIFFERENT METHODS
محتوى المقالة الرئيسي
الملخص
In this study regeneration process was carried out for exhausted activated carbon, which has been used for adsorption process of furfural from its solution by three different methods (washing with dilute alcohol ethanol 20%, washing with boiled distilled water at 100Co؛ and thermal processat (200 – 900) Co؛. The regenerated activated carbon has been reused in the column system of fixed
– bed in order to estimate the adsorption quantities and comparing the value with adsorptionquantity of original activated carbon under same condition (furfural with concentration 0.2 kg/m³,bed depth 5 cm, flow rate of liquid 16.16 × 10-5 m³/min and particular size of activated carbon (1.5-0.5) mm) in order to estimate the regeneration efficiency for each method which ranged (60-90)%.
تفاصيل المقالة
كيفية الاقتباس
تواريخ المنشور
المراجع
- Al- Saady, Niriys H.M, 2000, M.Sc. thesis , Baghdad university, College of Women.
-Carbochem´s report “Activated carbon”, June 2004, on www.earochem.com/activatedcarbon101.html..
- Casey T. J., 1992, “Unit treatment processes in water and wastewater engineering”, Wiley series New York.
- Clup R. L. and Gordon G. L., 1971, “ Advanced wastewater treatment “, New York, CH7-8.
- Clup R. L. and Gordon G. L., 1974, “ New concept in water purification”, New York, ch. 8.
- Foste R. and Leslie W., 1971, “ Encyclopedia of industrial chemical analysis”, John Wiely, New York, vol.13, p.232-239.
- Martine R. L., and W. J. Ng., 1984, J. of water Research, vol.. 18, no. 1, p. 59-73.
- Martine R. L., and W. J. Ng., 1985, J. of water Research, vol.. 19, no. 12, p. 1527-1535.
- OSHA, 2000, “ Occupational Safety and Health Administration of furfural”, U.S. Dep. of labor.
- Rao C. S., 1994, “ Environmental Pollution Control Engineering”, Wiley Eastern, 2nd, India.