REMOVAL OF COPPER ION FROM WASTEWATER BY FLOTATION

Main Article Content

Ahmed A. Mohammed
Farah I. Abed

Abstract

Several industrial wastewater streams may contain heavy metal ions, which must be effectively removal
before the discharge or reuse of treated waters could take place. In this paper, the removal of copper( II)
by foam flotation from dilute aqueous solutions was investigated at laboratory scale. The effects of
various parameters such as pH, collector and frother concentrations, initial copper concentration, air flow
rate, hole diameter of the gas distributor, and NaCl addition were tested in a bubble column of 6 cm inside
diameter and 120 cm height. Sodium dodecylsulfate (SDS) and Hexadecyl trimethyl ammonium bromide
(HTAB) were used as anionic and cationic surfactant, respectively. Ethanol was used as frothers and the
optimal removal conditions have been established. Successful removals about (98%) and (76%) could be
achieved for copper ions with SDS and HTAB, respectively. Copper removal reached about 80% under
the optimum conditions at low pH; at high pH it became as high as 98% probably due to the contribution
from the flotation of precipitated copper. It was found that the presence of NaCl in the solution reduced
the recoveries. Adding ethanol at 1% concentration increased the removal efficiency. From the results the
rate of flotation was found to be first order.

Article Details

How to Cite
“REMOVAL OF COPPER ION FROM WASTEWATER BY FLOTATION” (2011) Journal of Engineering, 17(06), pp. 1483–1491. doi:10.31026/j.eng.2011.06.14.
Section
Articles

How to Cite

“REMOVAL OF COPPER ION FROM WASTEWATER BY FLOTATION” (2011) Journal of Engineering, 17(06), pp. 1483–1491. doi:10.31026/j.eng.2011.06.14.

Publication Dates

References

Abryutin, D., and Strel, K., Investigation of regularities of ion flotation of copper with the use of sodium diethyldithiocarbamate, Russian Journal of Non-Ferrous Metals, 51, 85–88(2010).

Cho, Y.S., and Laskowski, J.S., Effect of flotation frothers on bubble size and foam stability, Int. J. Miner. Process, 64, 69-80

(2002).

Choi, S.J., and KIM, K.H., The improvement of the removal efficiency of foam flotation by synergistic effect of mixed surfactant solutions, Environment Technology, 19, 1151-1156(1998).

Doyle, M.F., Ion flotation—it is potential for hydrometallurgical operations, Int. J. Mineral Process, 72, 387–399(2003).

Eckenfelder, W., and Ford, D.L., Industrial water quality, 4th edition, McGraw-Hill, New York (2009).

Ghazy, S. E., El-moray, S. M., and Ragab, A.H., Ion flotation of copper (II) and lead (II) from environmental water samples, J. Appl. Sci. Environ. Manage. 12, 75 – 82(2008).

Lazaridis, N.K. , Peleka, E.N. , Karapantsios, T.D. ,and Matis, K.A. ,Copper removal from effluents by various separation techniques, Hydrometallurgy,74 ,49–156(2004).

Liu, Z., and Doyle, M.F., A thermodynamic approach to ion flotation, Colloids Surf. , 178, 79–92(2001).

Liu, Z.,and Doyle, M.F.,Ion Flotation of Co+2, Ni+2, and Cu+2 using dodecyldiethylenetriamine (Ddien), Langmuir, 25, 8927–8934(2009).

Matis, K.A., and Zouboulis, A.I., Flotation techniques in water technology for metals recovery: the impact of speciation, Separation Science and Technology, 36, 3777–3800, (2001).

Medina, P., Torem, M., and Mesquita, L., on the kinetics of precipitate flotation of Cr III using sodium dodecylsulfate and ethanol, Minerals Engineering, 18 225–231(2005).

Polat, H., and Erdogan, D., Heavy metal removal from waste waters by ion flotation, Journal of Hazardous Materials, 148, 267– 273(2007).

Sabti,H.,Brooks,R.R.,Stewart,R.B.and Hossain ,M., Adsorbing colloid flotation for removal of metal ions in waters from base metal mines, Environmental progress ,21, 63-69(2002).

Shakir, K., and Ahmed, F. , Removal of rhodamine (a basic dye) and thoron (An acidic dye) from dilute aqueous solutions and wastewater stimulants by ion flotation, Water Research, 44, 1449– 1461(2010).

Stoica, L., Oproiu, G.C., Cosmeleata, R. , and Dinculescu, M., Kinetics of Cu2+ separation by flotation, Sep. Sci. Technol., 38, 613–632 (2003).

Sulaymon, A., and Mohammed, A., Separation and hydrodynamic performance of air – kerosene-water system by bubble column, International journal of chemical reactor engineering, 8, 1-15 (2010).

Tchobanoglous, G., and Burton, F.L., and Stensel, D.H., Wastewater engineering treatment and reuse, McGraw-Hill Companies (2003).

Zhang, J., and Jing, Y., Removal of trace Cu2+ from aqueous solution by foam fractionation, Desalination, 249, 503–506 (2009).

Similar Articles

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)