Laboratory Study on the Effect of Water-Cement Ratio on Strength Characteristics of Jet Grouting Columns

محتوى المقالة الرئيسي

Fadhil W. AL-Malkee
Mahmood D. Ahmed

الملخص

Jet grouting is one of the most widely applied soil improvement techniques. It is suitable for most geotechnical problems, including improving bearing capacity, decreasing settlement, forming seals, and stabilizing slopes. One of the difficulties faced by designers is determining the strength and geometry of elements created using this method. Jet grouted soil-cement columns in soil are a complicated issue because they are dependent on a number of parameters such as soil type, grout and water flow rate, rotation and lifting speed of monitor, nozzle jetting force, and water to cement ratio of slurry. This paper discusses the effect of the water-cement ratio on the physical and mechanical characteristics of soilcrete. In the laboratory, sandy soil mixed with cement grout with water-cement ratio varies from (0.7:1 to 1.4:1). To evaluate the characteristics of soilcrete, 96 specimens were prepared in the laboratory and tested at different curing times. The results indicate that the Uniaxial Compressive Strength (UCS) of soilcrete decreases with increasing the (W/C) ratio of the grout, where the soilcrete strength of W/C ratio of 0.7 is higher about 237% of W/C ratio of 1.4 at 28-day; the evolution of the (UCS) is proportional to the logarithm of the curing time; the ratio between the modulus of elasticity (Etg50) to the maximum UCS varies from 113 to 175; when the water-cement ratio increases, the dry density of soilcrete decreases, as a result, the (USC) of soilcrete decreases.

تفاصيل المقالة

كيفية الاقتباس
"Laboratory Study on the Effect of Water-Cement Ratio on Strength Characteristics of Jet Grouting Columns" (2021) مجلة الهندسة, 27(12), ص 33–49. doi:10.31026/j.eng.2021.12.04.
القسم
Articles

كيفية الاقتباس

"Laboratory Study on the Effect of Water-Cement Ratio on Strength Characteristics of Jet Grouting Columns" (2021) مجلة الهندسة, 27(12), ص 33–49. doi:10.31026/j.eng.2021.12.04.

تواريخ المنشور

المراجع

• Akin, M. K. (2016) ‘Experimental studies on the physico-mechanical properties of jet-grout columns in sandy and silty soils’, Journal of African Earth Sciences, 116, pp. 190–197. doi: 10.1016/j.jafrearsci.2016.01.011.

• ASTM D1633 - 17 Standard Test Methods for Compressive Strength of Molded Soil-Cement Cylinders. Available at: https://www.astm.org/Standards/D1633.htm (Accessed: 9 July 2021).

• ASTM D2216 - 10 Standard Test Methods for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass. Available at: https://www.astm.org/DATABASE.CART/HISTORICAL/D2216-10.htm (Accessed: 14 July 2021).

• ASTM D2487 - 17e1 Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System). Available at: https://www.astm.org/Standards/D2487.htm (Accessed: 8 July 2021).

• ASTM D3080 / D3080M - 11 Standard Test Method for Direct Shear Test of Soils Under Consolidated Drained Conditions. Available at: https://www.astm.org/Standards/D3080 (Accessed: 9 July 2021).

• ASTM D4253 - 16e1 Standard Test Methods for Maximum Index Density and Unit Weight of Soils Using a Vibratory Table. Available at: https://www.astm.org/Standards/D4253 (Accessed: 9 July 2021).

• ASTM D4254 - 16 Standard Test Methods for Minimum Index Density and Unit Weight of Soils and Calculation of Relative Density. Available at: https://www.astm.org/Standards/D4254.htm (Accessed: 9 July 2021).

• ASTM D854 - 14 Standard Test Methods for Specific Gravity of Soil Solids by Water Pycnometer. Available at: https://www.astm.org/Standards/D854 (Accessed: 8 July 2021).

• Cardoso, R., Ribeiro, D. and Néri, R. (2017) ‘Bonding effect on the evolution with curing time of compressive and tensile strength of sand-cement mixtures’, Soils and Foundations, 57(4), pp. 655–668. doi: 10.1016/j.sandf.2017.04.006.

• Consoli, N. C., Cruz, R. C. and Floss, M. F. (2011) ‘Variables controlling strength of artificially cemented sand: influence of curing time’, Journal of Materials in Civil Engineering, 23(5), pp. 692–696.

• Croce, P., Flora, A. and Modoni, G. (2014) Jet grouting: technology, design and control. CRC Press.

• Falcão, J., Pinto, A. and Pinto, F. (2000) ‘Casos práticos de soluções de Jet Grouting vertical’, in VII Congresso Nacional de Geotecnia. Porto: Sociedade Portuguesa de Geotecnia.

• Da Fonseca, A. V., Cruz, R. C. and Consoli, N. C. (2009) ‘Strength properties of sandy soil-cement admixtures’, Geotechnical and Geological Engineering, 27(6), pp. 681–686. doi: 10.1007/s10706-009-9267-y.

• Dagys, A.; Medzvieckas, J.; Milvydas, R.; Sližytė, D. 2010. Using of jet grouting piles reinforced with central bars for low retaining walls, in 10th International Conference Modern Building Materials, Structures and Techniques: selected papers. Vol. 2. 19–21 May 2010, Vilnius, Lithuania.Vilnius: Technika, 1168–1173. ISBN 9789955285946.

• Fang, Y.S., Kuo, L.Y., Wang, D.R., 2004. Properties of soilcrete stabilized with jet grouting. In: Proceedings of the 14th International Offshore and Polar Engineering Conference, Toulon, France, May 23e28, 2004, pp. 696e702.

• Giménez, J. C. (2004) ‘Análisis de los factores que intervienen en la técnica del jet grouting’, Jornadas Técnicas SEMSIG-AETESS-4a Sessão-Mejora del Terreno Mediante Inyecciones y Jet-Grouting.

• Kimpritis, T. (2013) ‘“ The control of column diameter and strength in Jet Grouting processes and the influence of ground conditions ”. Thomas Kimpritis CID : 00680409 Supervisor : Dr . Jamie Standing Imperial College London , Department of Civil and Environmental Engineering ’, (September).

• Kosmatka, S. a. P. W., 1988. Design and control of concrete mixtures. 13th ed. Skokie, Illinois: Portland Cement Association.

• KUTZNER, C. (1996) ‘GROUTINGOF ROCK AND SOIL’. AA Balkema, Rotterdam, Netherlands.

• Lunardi, P. (1997) ‘Ground improvement by means of jet-grouting’, Proceedings of the Institution of Civil Engineers - Ground Improvement, 1(2), pp. 65–85. doi: 10.1680/gi.1997.010201.

• Nikbakhtan, B. and Ahangari, K. (2010) ‘Field study of the influence of various jet grouting parameters on soilcrete unconfined compressive strength and its diameter’, International journal of rock mechanics and mining sciences (1997), 47(4), pp. 685–689.

• Ökmen, Ö., 2003. A study on strength and deformation behavior of soilcrete in jet grout applications (Master's thesis, Middle East Technical University).

• Pearlman, S. (1998) ‘Jet grouting: New directions’, Civil Engineering, 68(8), p. 44.

• Van der Stoel, A.E.C., 2001. Grouting for Pile Foundation Improvement. PhD thesis. Delft University Press, p. 90.

• Xanthakos, P.P., Abramson, L.W., Bruce, D.A., 1994. Ground Control and Improvement. a Wiley-interscience publication John Wiley & Sons, Inc.

المؤلفات المشابهة

يمكنك أيضاً إبدأ بحثاً متقدماً عن المشابهات لهذا المؤلَّف.