REDUCTTON OF SO4-AND Cl-IONS FROM INDUSTRIAL WASTE WATER BY ION EXCHANGE
محتوى المقالة الرئيسي
الملخص
This rvork was conduuted to study the removal of ionic irnpurities from industrial wastewater, and more particularly those in the cotton textile industry. The wastewater considered here, contains both cation and anion impurities. The method used is ion exchange. The results showed that the equilibrium isotherm is strongly favorable type, and it fitted well with Langrnuir equation. Chlorine and Sulphate ions were reduced greatly but not with the same degree ( SOa- > Cl - ).
تفاصيل المقالة
كيفية الاقتباس
تواريخ المنشور
المراجع
Amera A. (2000), Single Point Controller, M.Sc. Thesis Submitted to University of Technology.
Dimiter D. (1996), An Introduction To Fuzzy Control, Springer-Verlag Berlin Heidelberg.
Gaith A (1997), Programmable Multi-Channel VME-Based Process Controller, M.Sc. Thesis Submitted to University of Technology
Mohammed M. (1993), Rule-Based Computer of Industrial Process Using Fuzzy Logic, M.Sc. Thesis Submitted to University of Technology.
Passino, Kevin M.. (1998), Fuzzy Control, Addison-Wesley Longman, Inc
Reznik, Leond: (1997), Fuzzy Controllers, Newnes.
Schultz, Thomas W. (1998), C and the 8051, Prentice Hall PTR